Braemar Error Codes

Complete error code reference for Braemar systems. Each error code includes severity level, description, and troubleshooting steps.

E1
URGENT
PCB Malfunction

Main circuit board failure or corruption

Turn off system immediately. Contact Braemar technician for board replacement.

Call Now
E2
URGENT
Gas Valve Error

Gas valve not responding or stuck position

Check gas supply at meter. Call service urgently.

Call Now
E3
URGENT
Ignition System Failure

Pilot light or igniter not functioning

Check pilot light access. Professional repair needed if no flame.

Call Now
E4
HIGH
Temperature Sensor Fault

Indoor/outdoor temperature sensor malfunction

Clean sensor. If error persists, sensor replacement required.

Call Now
E5
HIGH
Flame Detection Error

Flame rod not detecting combustion

System shutdown for safety. Call Braemar technician immediately.

Call Now
E6
HIGH
Blower Motor Issue

Main blower motor not operating

Check filter status. Verify motor power. May need replacement.

Call Now
E7
HIGH
Pressure Switch Fault

Vent pressure switch not triggering

Inspect ductwork for blockages. Clear obstructions.

Call Now
E8
HIGH
Draft Inducer Malfunction

Draft inducer motor failed

Check vent for ice/snow blockage. Professional inspection needed.

Call Now
E9
MEDIUM
Thermal Limit Activated

System overheat protection triggered

Allow cooling 30 mins. Check for blocked air returns.

Call Now
E10
HIGH
Gas Supply Low

Insufficient gas pressure detected

Contact gas supplier. Verify line pressure.

Call Now
E11
MEDIUM
Thermostat Communication

Thermostat not communicating with furnace

Replace thermostat batteries. Check wiring connections.

Call Now
E12
HIGH
Transformer Fault

24V transformer failure

Power cycle system. Transformer replacement needed.

Call Now
E13
HIGH
Capacitor Failure

Start or run capacitor damaged

Professional repair required. Do not attempt DIY.

Call Now
E14
MEDIUM
Motor Bearing Noise

Blower motor making grinding/squealing

Check lubrication. Motor replacement may be needed.

Call Now
E15
MEDIUM
Air Filter Clogged

Furnace filter severely restricted

Replace furnace filter immediately with correct MERV.

Call Now
E16
MEDIUM
Ductwork Blockage

Supply/return ductwork blocked

Check all vents and registers. Remove obstructions.

Call Now
E17
MEDIUM
Cycle Rate High

System cycling on/off frequently

Check thermostat. May indicate oversized system.

Call Now
E18
MEDIUM
Limit Switch Stuck

Temperature limit switch malfunction

Allow cooling. Check airflow. May need replacement.

Call Now
E19
URGENT
Gas Smell Detected

Gas odor near furnace/vents

Leave home immediately. Call gas company from outside.

Call Now
E20
URGENT
System Lockout

Safety lockout after multiple ignition failures

System in safety mode. Professional reset required.

Call Now
Preventative Care

Braemar Maintenance Tips

Regular maintenance helps prevent error codes and keeps your system running efficiently. Follow these Braemar-specific tips for optimal performance.

Still Need Help?

Our licensed technicians specialize in Braemar systems and are available 24/7 for emergency repairs and expert support.

Go Back Top